This is course 4 Lesson.
eQ DOE22 AES Structure |
DOE2 Structure Building, Space, Zone, System... |
Design Standards ASHRAE IES |
HDD65 = Heating Degree DaysBase 65oF M-Bld = Metal Building S-Frm = Steel Framed No-Swg = No Swing (Wood Framed not shown) CDD65 = Cooling Degree DaysBase 50 F Floors Roofs Walls... |
Operating Schedules |
$========================================================================$ $ DOE Hospital Operating Schedules / Profiles , November 1979 $ $ WD = Weekdays (M-F) $ $ WEH =... |
Energy Saving Options |
CASE STUDIES of BUILDING TYPES (greater than 300,000 sq.ft. - 500 Tons @600 sq.ft. per Ton) Training Examples based on DOE2.1E and eQUEST (DOE2.2) To Compare Systems-Plant Options... |
Typical Utility - Rate Formats |
PEPCO : Potomac Electric Power Company, Washington DC Washington Gas... |
Building Cost Data for LCCA |
Heating Costs R.S. MEANS Mechanical Cost Data - 2001 Electric Boilers KW MBH HW Steam $ $ 6 20 4,625 9,675 9 31 4,650 10,100 18 61 10,100 24 82 4,975 10,300 30 102... |
Pipe Data - Steel |
Pipe Sizing Criteria Schedule 40 Steel S-40 Steel Design 3'/100' PD, 10 fps vel - High: 5'/100' PD, 12 fps vel Max: 7'/100' PD, 15 fps vel Nom Outs Wall Ins Design High Maxim... |
Pipe Data Copper |
Nominal Type K Copper Type L Copper Type M Copper Pipe Sizing Criteria Pipe Size Diameter (ins) Diameter (ins) Diameter (ins) Velocity Loss in Flow (ins) Outside Inside Outside... |
Pipe Data - CI Brass Alum PVC |
CAST IRON Physical Data Hydraulic Handbook Colt Industries Nominal 125 PSI Cast Iron 175 PSI Cast Iron 250 PSI Cast... |
Pipe Data - Valves Fittings |
Dynamic Pressure Losses through Valves EL = L/D* D (EL = Equivalent Length. L=Pipe Length, D = Pipe Diameter) Velocity Pressure Factor (K) for Water : K = C*D**E: Pressure Drop (PD... |
Pipe Design - Fluids |
.distance td {padding-left: 7px;background-color: #ffffcc;} .no-distance td {padding-left: 0px;background-color: white;} .blue-cell {background-color: #ccffff;border-left: 3px solid... |
Pipe Design - Steam Condens |
STEAM PRESSURE CLASSIFICATION AND PIPE SIZING DESIGN CRITERIA .distance td{padding-left: 7px;} .no-distance td{padding-left: 0px;} .blue-cell{background-color: #ccffff;border-right:... |
Pipping Design - Plumbing |
.distance td{padding-left: 7px;} .no-distance td{padding-left: 0px;} Fixture Data : Domestic Hot and Cold Water Fixture Type Supply Minim Fixture Private Use : Fixture Units... |
Example of Primary-Secondary Piping Network System |
|
Natural Gas Pipe Sizing Tables and Charts |
Steel Pipe - Schedule 40 .custom-border-grey td{border: 3px solid #cccccc;} Downstream Pressure Press Pipe Dimension (in) (psig) 1/2" 3/4" 1 1 1/4 1 1/2 2 2 1/2 3 4 5 9.... |
Pipe Sizing - Charts |
Design Criteria: 3' Frictional Pressure Drop per 100' Pipe Length with a Maximum Velocity of 10 ft/sec Figure - 1 Friction Loss for CLOSED Piping Systems: Schedule 40 Steel... |
Duct Sizing - Charts & Tables |
CHART 7 - FRICTION LOSS FOR ROUND DUCT TABLE 6 - CIRCULAR EQUIVALENT DIAMETER,* EQUIVALENT AREA AND DUCT CLASS OF RECTANGULAR DUCTS FOR EQUAL FRICTION TABLE 6 -... |
Pumps Fans - Analysis Forms |
.dist{text-align: initial;padding-left: 10px;} FAN PERFORMANCE Examples Calculated by Program D E S C R I P T I O N Fan - 1 Fan - 2 Fan - 3 Fan - 4 Fan - 5 Identification... |
ASHRAE IESNA CFR Criteria |
.dist{padding-left: 3px;text-align: initial;} .dim td{width: 44px;} .dist5px{text-align: initial;padding-left: 5px;} .dim2{width: 66px;} .dist7px td{text-align: initial;padding-left:... |
LEED<sup>™</sup> Scorecard |
.cell {text-align: center;border: 2px solid #bfbfbf;background-color: #ccffcc;font-weight: bold;} .small-grey-text {font-size: 12px;padding-left: 5px;color: #949494;} .align-left{text... |
Copyright © 2010-2024 CosmoLogic LLC. TRACE 700 and eQUEST are ™ of Trane Inc. and James J. Hirsch respectively. Energy-Models.com is built in San Francisco, CA and Slinger, WI USA.