The Real Effect of Lighting on Energy and LEED points

as the heating is provided using low cost fossil fuels (relative to electricity) or if heat pumps are used ... reading my blog?" Okay, maybe I'm being harsh again but it's really simple math and I ... and in heating when the heat is non-electric. Remember, lights give off heat and therefore increase the amount ...

eQUEST for LEED Case Study - Part 3

with separate HVAC system. Well interestingly enough we have two systems. However one of them is a heat pump which we need to get rid of because this says nothing about heat pumps. So remember that; the number ... have two systems, but one of them is a heat pump which we need to get rid of because this says nothing ...

Beat the Heat - How to save energy - In hot weather

hemisphere) - shame on your designer/architect (unless it is a heat pump). Consider shading it with a trellis ... for several reasons Cooking produces a lot of heat and also a lot of steam. Excess moisture in your house makes it feel warmer than it is. So, grilling outside can both eliminate the heat, and the moisture ...

exhaust air liquid heat recovery loop

it would be a heat pump to make hot and cold Integrated Chiller - Konvekta AG We?re primarily seeing the runaround type or plate-and-frame direct heat exchange instead of using a heat pump to boost ... Efficiency Consultants and Sustainable Design Engineers grummanbutkus.com | Blog | Facebook | ...

Impact of Cooling Tower EEM on Space Cooling load

then the compressor energy of the individual heat pumps would go down. David David S. Eldridge, Jr., P.E., ... When you say loads, do you mean the end-use energy breakdown totals? (Loads = heat/cooling gains in the spaces ? VFDs should not be affecting heating or cooling loads.) If the change to the tower fan ...

Webinar from Chicago Chapter of IBPSA-USA: Ground Loop Heat Pump System Design and Modeling Tools

of Ground Loop Heat Pump System Design and Modeling Tools. ... and simulating a ground loop heat pump system can often be part of a high performance building design. ... Ground-Coupled Heat Pumps), that can help evaluate designs. Our presenters will be: * Scott Hackel, ...

Why Water Source Heat Pump is not considered as Renewable Energy in LEED rating system?

In the United States geothermal heat pumps - I'll refer it to them ... pump units and some are in heating while others are in cooling. I don't think this affects ... ground-coupled heat pumps, and the effect of harvesting from these sources would generally be seen as negligible ...

High pumps equivalent full load hours in the model

perhaps a DOAS unit with heat recovery. (One clue would be does the proposed building also have a DOAS ... Energy Efficiency Consultants and Sustainable Design Engineers grummanbutkus.com | Blog | ...

Pump and Flow sizing issue

is less than the baseline ?T then you should expect a penalty on pumping energy. 2. Any penalty ... comparison to baseline. 3. Review the assumptions in the baseline that generate a heating load ? AHU coil sizing, OA quantities, and reheat control strategy, other heat consuming components of your ...

NECB - MURB Reference Heating Type

used air-to-air heat pumps with electric resistance heat, which makes sense that a TTW unit in practice is going to be heat pump and/or electric resistance heat. A furnace option would not be part of a TTW unit ... that on an annual basis the WLHP system takes primary heat from the boiler more than the compressors for cold ...