6 tips for Reducing Unmet load hours

is not your throttling range! (such tip 5 our 6 tips for unmet hours blog, such tip 5 our 6 tips for unmet hours blog) (tips, unmet load hours) ... Unmet Load Hours (aka “The Bane of the Completed Simulation”)      What is an unmet load ...

Solving Unmet hours - 7 Step Approach

such as tip #5 in our 6 Tips for Unmet Hours blog ). Of my two “failures”, one was a bug. The other ... Nearly every energy modeler on the planet will ask at some point, “How do I solve unmet hours?” Well, the rookie question would be “Which setting do I change to get rid of unmet hours?” or even better ...

Trane TRACE 700 + LEED Part 1: Prepping the Proposed Building

this. Modeler’s Enemy No. 1: Unmet Hours 11:05 In the course description we mention unmet hours without realizing that some people don’t know what an unmet hour is. Basically an unmet hour is any hour where the model has one room that is not at its set point. Unmet hours are actually poorly ...

TRACE 700 users must know these 7 things

equipment, and Unmet hours 2 - Reduced year weather Currently, all Default weather in TRACE is reduced year weather. This means that the weather contains only 1440 hours of data, versus the total hours ... efficiently). While I can't adequately address how to use templates in this blog, I can mention this: TRACE ...

Guest Post

or creative unmet hour solutions. Here is an example from Colin Evans, one of our guest contributors: ... off LEED reviewers? We want to hear about it. Guest Blogs Are you a regular Bill Shakespeare, ... on the Energy-Models blog! ...

Mailing List Meet-up during ASHRAE Building Performance Analysis Conference and SimBuild

are organizing a meet-up. Everyone is welcome with the intended audience being participants from UnmetHours ... has happy hour until 6:30 p.m. so don't take too long. Depending on the venue we can reserve ... grummanbutkus.com | Blog | Facebook | Twitter (eQUEST, equest users) ...

Baseline Fan Energy Very High

the proposed case to run fewer hours or running much longer at part-load if the proposed case has that capability - maybe add a report to see the load profile for the two cases. Another check is that unmet hours and temperature plots in the SS-O report were consistent between the two cases providing equal ...

Mailing List Meet-up during ASHRAE Building Performance Analysis Conference and SimBuild

are organizing a meet-up. Everyone is welcome with the intended audience being participants from UnmetHours ... has happy hour until 6:30 p.m. so don't take too long. Depending on the venue we can reserve ... grummanbutkus.com | Blog | Facebook | Twitter (General Discussion, bldg sim) ...

Baseline Fan Energy Very High

Another check is that unmet hours and temperature plots in the SS-O report were consistent between ... fans. You can calculate the Effective Full Load Hours (EFLH) of the baseline fan as a ratio ... be slightly higher than the number of hours per year that your building is occupied since, following 90.1 ...

eQUEST for LEED Case Study - Part 3

this report we can get our unmet hours and notice we have 190 unmet hours in our heating range and there’s ... was 372,000 BTU hours and the other one was 347,000. Incidentally, both of those are dead center or between ... this is at least 100,000 BTU hours greater than the lower end, and we know that no matter what we do, we’re most ...